波多野结衣在线播放,久久精品无码AV一区二区三区,久久久久亚洲波多野结衣

      1. 
        

          (M)OV-C precise oven

          ±1.5℃ deviation at 200℃ Your best choice of high temperature aging or burn-in testing device at Terchy


          1.Accurate temperature deviation
           

          Temperature deviation OV-C CK-B
          50℃~100℃ ±1.0℃ ±2.0℃
          101℃~200℃ ±1.5℃ ±3.0℃
          201℃~250℃ ±2.0℃ ±4.0℃

          2.Multi options of interior volumes to meet your products aging needs.

          3.Uniform heat in test room

          4.Fast and uniform cooling by forced air refreshment 
           
          Applications: 
          High temperature test and heat treatment process in aviation, automobile, electrician and electronics, materials, energy, chemical industry, medical treatment, pharmaceutical and other industries

           

           

          Standard complied

          GB/T 2423.2-2008 ( IEC 60068-2-2:2007) test B:dry heat

           

          MODEL OV-CE
          VOLUME/CODE 64 216 512 1000
          CONTROL SYSTEM Smart temperature and humidity balance system 
          TEMPERATURE RANGE RT+10℃~+250℃
          TEMPERATURE DEVIATION ±1.0℃(50℃~100℃)
          ±1.5℃(101℃~200℃)
          ±2.0℃(201℃~250℃)
          Sensor location to wall distance is 1/10 of chamber interior dimensions.(≧50mm)
          TEMPERATURE CONSTANCY ±0.5℃
          HEATING TIME
          (WHEN EMPTY IN WORK SPACE)
          RT?+250℃   about 60min
          COOLING TIME
          (WHEN EMPTY IN WORK SPACE)
          250℃ ?+50℃  about 80min
          INTERIOR DIMENSIONS
          (WxHxD)CM
          40×40×40 60×60×60 80×80×80 100×100×100
          EXTERIOR DIMENSIONS
          (WxHxD)CM
          123×95×85 143×115×105 163×135×125 183×155×145
          UUT SHLEF NUMBER 2 2 2 2
          INTERIOR MATERIAL stainless steel #430
          EXTERIOR MATERIAL paint coating steel plate
          COOLING SYSTEM glass wool
          CONTROLLER  programmable ST-570 temperature controller  
          SAFETY DEVICES overheat protection, motor overload protection, fan overcurrent protection, trouble indication, NFB 
          ACCESSARIES  one power cable(2.5m long)
          POWER AC 1ф2W+G 220V±10% 50HZ AC 3ф4W+G 380V±10% 50HZ 
          NOTES:
          (1)Ambient: setup room should be well-ventilated, temperature 5?35℃ and relative humidity ≤75%RH.
          (2)Sensor measurement method comply with IEC 60068-3-6:2001/ GB/T 2424.6-2006 / JTM K09 :2009. Parameters measured when sensor location to wall distance is 1/10 of chamber interior dimensions. 
          (3)Pics and spec for reference only. For more details please contact your sales rep.    

           

          MODEL MOV-CC
          VOLUME/CODE 64 216 512 1000
          CONTROL SYSTEM Accurate temperature regulation system 
          HUMIDITY RANGE RT+10℃~+250℃
          TEMPERATURE DEVIATION ±1.0℃(50℃~100℃)
          ±1.5℃(101℃~200℃)
          ±2.0℃(201℃~250℃)
          Sensor location to wall distance is 1/10 of chamber interior dimensions.(≧50mm)
          TEMPERATURE CONSTANCY ±0.5℃
          HEATING TIME
          (WHEN EMPTY IN WORK SPACE)
          RT?+250℃  about 60min
          COOLING TIME
          (WHEN EMPTY IN WORK SPACE)
          +250℃ ?+50℃  about 80min
          INTERIOR DIMENSIONS (WxHxD)CM 40×40×40 60×60×60 80×80×80 100×100×100
          EXTERIOR DIMENSIONS (WxHxD)CMCM 123×95×85 143×115×105 163×135×125 183×155×145
          UUT SHLEF NUMBER 2 2 2 2
          INTERIOR MATERIAL stainless steel #430
          EXTERIOR MATERIAL paint coating steel plate
          COOLING SYSTEM glass wool
          COOLING SYSTEM  programmable SRS5-P-P10 temperature controller 
          SAFETY DEVICES overheat protection, motor overload protection, fan overcurrent protection, trouble indication, NFB 
          ACCESSARIES  one power cable(2.5m long)
          POWER AC 1ф2W+G 220V±10% 50HZ AC 3ф4W+G 380V±10% 50HZ 
          NOTES:
          (1)Ambient: setup room should be well-ventilated, temperature 5?35℃ and relative humidity ≤75%RH.
          (2)Sensor measurement method comply with IEC 60068-3-6:2001/ GB/T 2424.6-2006 / JTM K09 :2009. Parameters measured when sensor location to wall distance is 1/10 of chamber interior dimensions. 
          (3)Pics and spec for reference only. For more details please contact your sales rep.    

           

          MODEL MOV-CZ
          VOLUME/CODE 64 216 512 1000
          CONTROL SYSTEM Accurate temperature regulation system 
          TEMPERATURE RANGE RT+10℃~+250℃
          TEMPERATURE DEVIATION ±1.0℃(50℃~100℃)
          ±1.5℃(101℃~200℃)
          ±2.0℃(201℃~250℃)
          Sensor location to wall distance is 1/10 of chamber interior dimensions.(≧50mm)
          TEMPERATURE CONSTANCY ±0.5℃
          HEATING TIME
          (WHEN EMPTY IN WORK SPACE)
          RT?+250℃  about 60min
          COOLING TIME
          (WHEN EMPTY IN WORK SPACE)
          +250℃ ?+50℃  about 80min
          INTERIOR DIMENSIONS
          (WxHxD)CM
          40×40×40 60×60×60 80×80×80 100×100×100
          EXTERIOR DIMENSIONS
          (WxHxD)CM
          123×95×85 143×115×105 163×135×125 183×155×145
          UUT SHLEF NUMBER 2 2 2 2
          INTERIOR MATERIAL stainless steel #430
          EXTERIOR MATERIAL paint coating steel plate
          INSULATION MATERIAL glass wool
          CONTROLLER Terchy S3503 color 3.5 inch LCD touch screen controller
          SAFETY DEVICES overheat protection, motor overload protection, fan overcurrent protection, trouble indication, NFB 
          ACCESSARIES one power cable(2.5m long)
          POWER AC 1ф2W+G 220V±10% 50HZ AC 3ф4W+G 380V±10% 50HZ 
          NOTES:
          (1)Ambient: setup room should be well-ventilated, temperature 5?35℃ and relative humidity ≤75%RH.
          (2)Sensor measurement method comply with IEC 60068-3-6:2001/ GB/T 2424.6-2006 / JTM K09 :2009. Parameters measured when sensor location to wall distance is 1/10 of chamber interior dimensions. 
          (3)Pics and spec for reference only. For more details please contact your sales rep.    

           